Pioneers in the industry, we offer 1 wire current loop transmitter and din rail temperature transmitter from India.

1 Wire Current Loop Transmitter

1 Wire Current Loop Transmitter
  • 1 Wire Current Loop Transmitter
  • 1 Wire Current Loop Transmitter
  • 1 Wire Current Loop Transmitter
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Usage/ApplicationEnvironmental Monitoring
Model Name/NumberTSA200
BrandTeracom
Operating Range0 to 20 mA
Rated Supply Voltage4.5 to 5.5 V
Dimensions85 x 35.1 x 23.5 mm
Maximum supply current (1-Wire bus)40 mA
Resolution0.01 mA

1-Wire 0-20/4-20mA current loop transmitter with galvanic isolation

Features


  • Galvanic isolated current loop input from 1-Wire interface
  • 10-bit resolutions
  • Excellent long-term stability
  • IP30 ingress protection
  • Very low current consumption
  • Unique 64-bit serial number for multi-sensors support

Applications


  • Air pressure monitoring for industrial processes
  • High-temperature monitoring in bakeries and dryers
  • Heating, ventilation and air conditioning (HVAC) systems
  • High current monitoring with split core transducers for industrial processes 
Request
Callback
Yes! I am interested

Din Rail Temperature Transmitter

Din Rail Temperature Transmitter
  • Din Rail Temperature Transmitter
  • Din Rail Temperature Transmitter
  • Din Rail Temperature Transmitter
  • Din Rail Temperature Transmitter
  • Din Rail Temperature Transmitter
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Output Type2-Wire,4 to 20 mA Current Loop
Thermal Drift25 ppm / Degree C
Sensor ConnectionsScrew Terminals
LinearisationBS EN 60751(IEC 751) Standard/JISC 1604
Output Range4 to 20 mA

Features
Lead Resistance Compensation for Pt100
(Up to 5Ω in Each lead)
Cold-Junction Compensation for Thermocouples
(Accuracy Better than ± 0.5°C)
Measurement Accuracy : ± 0.1°C ± 0.05% of Reading
Selectable High / Low Burnout Current
(For Versions 2, 3 & 4)
Supply Voltage : 12 to 36 VDC (24 VDC Nominal)
Loop Current Output : 4 to 20 mA (Non Isolated)
Response Time :
82 mS for Version 1
250 mS for Versions 2, 3 & 4
Maximum Output Load :
[ (Vsupply - 10) / 22 ] KΩ (Example : 636Ω @ 24 VDC)
RS485 Communication Port with Free PC Software Tool for
Easy Configuration (For Versions 2, 3 & 4)
Request
Callback
Yes! I am interested
X

Product Videos

Explore More Products

View All Products
Tell Us What Are You Looking For ?




Reach Us
Satish Bhat (General Manager)
Process Precision Instruments
1st Floor, 101, B/H Shakti Complex, Diamond Industrial Estate, Navghar, Vasai Road East
Palghar - 401210, Maharashtra, India
Get Directions

Call Us


Send E-mail